Skip to Main Content
RAM Structural System Ideas

Welcome to the RAM Structural System Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

Showing 95 of 95

User Customizable Cp Leeward Value

Allow for users to specify/override the Cp Leeward value in ASCE 7 wind generation to account for buildings built as additions to existing structures or allow for future additions to the current model. Current wind generation is unconservative in ...
Tim Liebhold 8 months ago in  2 Needs review

Additional curtains to shear wall bar template

The shear wall module bar template is limited to 3 curtains. Please increase to 5 or more.
Guest 8 months ago in  0 Needs review

I have a suggestion/idea. Why can't the program allow the user to open multiple windows in RAM SS?

I have a suggestion/idea. Why can't the program allow the user to open multiple windows in RAM SS? It helps the user to understand more in a better way. As a beginner users will make mistakes or errors and it will make it easy for them to understa...
Guest 9 months ago in  2 Needs review

Applying lateral line loads over a beams or columns under Wind load case

Applying lateral line loads over beams or columns under Wind load case. Can we apply line loads over beams or columns under the Wind load case? Attached snip for ref. Since grid A is the outer face of the building we have a roof canopy beyond grid...
Guest 9 months ago in  1 Future consideration

User selects steel panel zone capacity equations

Setting the rigid end zone to 0% reduction consistent with the panel zone element assignment causes RAM to use the first set of equations for panel zone shear capacity (panel-zone deformation effect on stability ignored). I think the user to speci...
Guest 9 months ago in  2 Needs review

Clear column sizes in modeler elevation view.

When running schematic designs, I want to reset sizes when adding additional lateral frames. Currently, the only way to clear out sizes is to fence plan by plan. It would be much faster to do this by elevation.
Guest 9 months ago in  0 Needs review

RAM SS - All Modules

Add the Modeler Features "Set Show Options" and "Measure Distance" tools to all of the the other RAM SS Modules.
Guest 10 months ago in  0 Needs review

RAM Concrete Beam Module - Copy Reinforcing

Provide a command to copy beam span reinforcing for beam span to adjacent Beam Line similar to the "Copy beam line to beam line." This is a "time saving" feature. This feature would need to "overlook" beam lentgh differeces.
Guest 10 months ago in  0 Needs review

RAM Concrete Beam Module - Effective Depth d for different Beam Directions

It is common to set the primary steel effective depth "d" at one depth for all beams in one direction (ie, North / South). The used a different effective "d2" depth for the transverse beams reinforcing steel (ie, East / West) to pass below. This c...
Guest 10 months ago in  0 Needs review

Concrete Column view/update options

Within the concrete column view update, the following improvements to be implemented - Display the story name (i.e. PH Roof) instead of just story number, including the size. The ability to change the size and even define new sizes (e.g. 18x36, 18...
Guest 10 months ago in  0 Needs review