Skip to Main Content
RAM Structural System Ideas

Welcome to the RAM Structural System Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

Showing 129 of 129

Do not clear steel beam sizes when changing noncomposite to composite.

Do not clear steel beam sizes when changing non-composite to composite. I'm not sure if this is deliberate or a bug, but members with assigned sizes can be changed from composite to non-composite in the modeler without losing their assignment. How...
Guest 3 days ago in  1 Needs review

Design cantilever extension with different sizes

In the steel beam module, allow a different size for the cantilever and backspan when modeled as "extensions".
Guest 6 days ago in  0 Needs review

Torsion Capacity Reporting

See PRODUCT BACKLOG ITEM 1677993 In RAM Concrete Beam and Column, we report 0.75*Tn, which is actually 0.75*Tth (see ACI 318-19 22.7.4.1). I recommend using that notation in Concrete Beam and Column Design reports when ACI 318-14 or ACI318-19 is u...
Guest 12 days ago in  0 Needs review

export concrete column design forces

Currently, the concrete column design forces report only shows dead and live loads, but I would like to get combination loads that may include wind, seismic, etc.
Guest 12 days ago in  0 Needs review

RAM Frame - Assign > Parapet

Provide the ability to assign a parapet/roof screen/roof projection graphically in RAM Frame for the purposes of customizing the exposure at each top level of a building structure.
Guest 12 days ago in  0 Needs review

Custom Load Combinations in RAM Steel Beam/Steel Column

Please add the ability to generate load combinations and create custom load combinations in RAM Steel Beam and RAM Steel Column for the gravity loads. Updated codes and additional requirements (such as the need to incorporate FM Global datasheets)...
Guest 12 days ago in  0 Needs review

Add special boundary element design for shear walls with Hw/Lw < 2. ACI 318-19 Section 18.10.6.3

In the concrete wall module, special boundary element zone requirements are only checked against the displacement method (ACI 18.10.6.2). In ACI 318-14 and 19 section 18.10.6.2 is directed at slender walls with Hw/Lw >= 2. If the aspect ratio o...
Guest 23 days ago in  1 Future consideration

Zoom With Mouse Scroll in RAM Beam

RAM Beam needs to allow zoom with mouse scroll similar to other RAM modules.
Guest over 3 years ago in  3 Future consideration

Allow user assigned steel beam camber

As part of user assigned beam sizing, occasionally would like to override the default camber value reported.
Guest over 3 years ago in  0 Needs review

Maximize embodied carbon reductions in design optimization

I'm working on reducing the embodied carbon of a project of mine, and I'm having to compare column systems, between WF columns and HSS. WF columns have significantly lower embodied carbon (~60% reductions when using the same weight of steel), so I...
Guest 3 months ago in  1 Future consideration