Skip to Main Content
RAM Structural System Ideas

Welcome to the RAM Structural System Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

Bring RAM SS into the 21st century

It's now 2024, many if not all of the requests in this forum have been open requests for YEARS and in some cases over a DECADE. Why is this program not being updated other than for new code requirements? Wind uplift still has not been implemented ...
Joshua Few almost 3 years ago in  2 Needs review

Merge user wind cases RAM generated wind cases

Often, roofs are more complex than flat, full-plate diaphragms with uniform parapet heights on all sides. When a single parapet height assignment in RAM Frame isn't accurate enough, the user needs to define additional wind loads. I would like to m...
Guest 3 months ago in  0 Needs review

Save diaphragm section cuts

In frame, allow defined section cuts for diaphragms to be saved rather than redrawn every time.
Guest 3 months ago in  1 Planned

Keyboard shortcuts for RAM Modeler similar to CAD

Provide keyboard shortcuts for RAM Modeler similar to CAD to speed up time it takes to create a model.
Guest over 4 years ago in  1 Needs review

Implement National Building Code of Canada 2025 Load Combination Changes

In the newly adopted NBCC2025, load factors from gravity load combinations are being changed. In Canada, RAM will be incorrect/obsolete on all projects moving forward unless the load combinations are addressed.
Guest 3 months ago in  1 Future consideration

Wind Uplift in RAM Frame

Add wind uplift load cases to RAM Frame.
Guest over 4 years ago in  2 Future consideration

Add tornado wind loads.

Beginning in ASCE 7-22/IBC 2024, structural designs must consider tornado wind loads for essential facilities. The calculation of these loads and the associated load combinations should be added to RSS.
Guest over 1 year ago in  0 Future consideration

When moving a column on one level include an option that also moves it on other levels.

When a column is moved it only moves on one level which makes you chase down data check errors when columns are misaligned. When column locations change it would be nice to have the option to move it on all levels and not just the one selected.
Guest 8 months ago in  1 Future consideration

Design cantilever extension with different sizes

In the steel beam module, allow a different size for the cantilever and backspan when modeled as "extensions".
Guest 8 months ago in  0 Needs review

Generation of Wind Load for non-regular building shapes (e.g., C, L, and U shaped floor plates)

We don't see many rectangular structures these days. Would be great if RAM Frame could generate wind loads for non-regular building shapes (e.g., "C", "L", & "U" shaped floor plates). This would be a time-saver having not to hand calculate and...
Guest over 4 years ago in  1 Needs review