All ideas

Showing 109 of 109

Apply Lateral Point(Nodal)/Line Loads Logically

Below is a list of thoughts about lateral point(nodal)/line loads. Incorporating any of the below ideas would be helpful. 1. Allow the user to apply lateral line loads as well as lateral point(nodal) loads. 2. Allow the user to apply lateral point...
Guest 3 months ago in  0 Needs review

Change the way data is exported to CSV/Excel format

Currently when the user exports data to CSV, it's basically a text version of the pdf data output. The organization of data is difficult to post-process because the data has page headers based on load cases and combinations (among other items). At...
Joshua Few about 2 months ago in  2 Needs review

Wind Uplift in RAM Frame

Add wind uplift load cases to RAM Frame.
Guest over 2 years ago in  1 Future consideration

Import DWG drawings to be used as a reference layout in RSS, similar to what you do in Ram Concept.

When you are defining a floor in RSS, it would be very useful to be able to import drawings in DWG formats to be used as a template or reference file to define the floor data. You can do this in Ram Concept.; why not in RSS?
M Portillo over 2 years ago in  1 Needs review

Generation of Wind Load for non-regular building shapes (e.g., C, L, and U shaped floor plates)

We don't see many rectangular structures these days. Would be great if RAM Frame could generate wind loads for non-regular building shapes (e.g., "C", "L", & "U" shaped floor plates). This would be a time-saver having not to hand calculate and...
Guest over 2 years ago in  1 Needs review

Add Wood Framing to Ram SS

Please add the ability to model and design wood beams in Ram SS. We design many structures that are a combination of wood, concrete and steel, and including design of wood members would not be difficult to incorporate. It would help RAM catch up w...
Guest over 1 year ago in  4 Future consideration

use ram frame to apply wind loads to non-diaphragm members

The ability to flag a member as a wind girt so wind loading is applied to the member if a diaphragm is not present.
Guest over 2 years ago in  0 Needs review

Option to include lateral triangular loads (earth pressure) on Wall at RSS

The idea is to have the option to include lateral loads on walls at RAM Structural system. There are a lot of projects with underground floors (garage) that have concrete walls to retain the earth around it Gustavo
Gustavo Vasconcellos over 2 years ago in  0 Needs review

Updating Cracked Factors in Ram Modeler should not delete wall design groups/section cuts/rebar assignments in RAM Concrete Wall

Currently, if the user sets up wall designs in Ram Concrete Wall, updating the cracked factor in RAM Modeler deletes all Concrete Wall groups/section cuts/rebar assignments/etc stating that "the geometry of the wall was updated." This gets extreme...
Joshua Few 5 months ago in  1 Planned

Wall Design - too many redundant design warnings

I don't need multiple design warnings for the same condition. For example, I have an out-of-plane shear strength warning for one of my segments. I have 26 warnings (associated with 26 combinations) for the same condition. The "worst" one listed in...
Guest 3 months ago in  0 Needs review