Account for wall transfer loads on one-way deck

As far as I am aware, RSS does not track the load transfer when a wall is sitting on a one-way deck without a supporting beam or wall directly below. The loads from the wall above the deck is "lost". My firm does a lot of multi-family construction...
Brian Genduso Genduso over 2 years ago in  0 Needs review

RAM SS-Option to turn off transverse beams bracing the bottom flange of support member

Similar to RAMS beam, I'd like an option to globally or individually turn off the bottom flange bracing of beams framing into a support member in the Gravity module. This is somewhat taken care of in the lateral frame module, where you can assign ...
Jared Ganstine Ganstine over 2 years ago in  0 Needs review

Flexibility in modifying the tributary height for Wind Load exposure for buildings with varying levels of diaphragms

RAM wind load currently gets applied taking the trib height as half the difference between the two levels. It would be tremendously useful if there was an option to modify the trib height, thereby playing with full height or partial height exposur...
Guest over 2 years ago in  0 Needs review

sideplate slows down transitions

Models with large quantities of sideplate connections exhibit huge delays when changing between operations (show member info, view update, assignments, etc.). This extends to the concrete module which has nothing to do with steel. This issue has p...
Guest 7 months ago in  0 Needs review

Concrete Column view/update options

Within the concrete column view update, the following improvements to be implemented - Display the story name (i.e. PH Roof) instead of just story number, including the size. The ability to change the size and even define new sizes (e.g. 18x36, 18...
Guest almost 2 years ago in  0 Needs review

3D Wind Load View

It would be nice to be able to see the wind pressures on the 3D view of the building.
Jaime Kafader over 2 years ago in  2 Needs review

Slab Penetration Layout - Adjustable View Box

In RAM Modeler, the Layout>Slab>Slab Penetration Layout dialog box is not adjustable - it would be beneficial to be able to make this view different sizes when you work on a project with a large amount of slab penetrations. For example the a...
Hunter Butler over 2 years ago in  0 Needs review

Only show column size tag once if column is continuous floor-to-floor.

In SColumn 3D view, viewing the column sizes shows labels at each floor. The labels often overlap (especially at HSS columns) and it is difficult to see. Recommend only showing the size tag once if the column is not spliced. Other parameters (Lb, ...
Guest over 1 year ago in  0 Needs review

Clear column sizes in modeler elevation view.

When running schematic designs, I want to reset sizes when adding additional lateral frames. Currently, the only way to clear out sizes is to fence plan by plan. It would be much faster to do this by elevation.
Guest over 1 year ago in  0 Needs review

RAM SS - All Modules

Add the Modeler Features "Set Show Options" and "Measure Distance" tools to all of the the other RAM SS Modules.
Guest over 1 year ago in  0 Needs review