Add Wall Thickness To Steel Column Trial Group

Add wall thickness to steel column trial group.
Guest 6 days ago in  0 Needs review

When moving a column on one level include an option that also moves it on other levels.

When a column is moved it only moves on one level which makes you chase down data check errors when columns are misaligned. When column locations change it would be nice to have the option to move it on all levels and not just the one selected.
Guest 22 days ago in  0 Needs review

Design cantilever extension with different sizes

In the steel beam module, allow a different size for the cantilever and backspan when modeled as "extensions".
Guest 29 days ago in  0 Needs review

Custom Load Combinations in RAM Steel Beam/Steel Column

Please add the ability to generate load combinations and create custom load combinations in RAM Steel Beam and RAM Steel Column for the gravity loads. Updated codes and additional requirements (such as the need to incorporate FM Global datasheets)...
Guest about 1 month ago in  0 Needs review

Do not clear steel beam sizes when changing noncomposite to composite.

Do not clear steel beam sizes when changing non-composite to composite. I'm not sure if this is deliberate or a bug, but members with assigned sizes can be changed from composite to non-composite in the modeler without losing their assignment. How...
Guest 26 days ago in  1 Needs review

RAM Frame - Assign > Parapet

Provide the ability to assign a parapet/roof screen/roof projection graphically in RAM Frame for the purposes of customizing the exposure at each top level of a building structure.
Guest about 1 month ago in  0 Needs review

Zoom With Mouse Scroll in RAM Beam

RAM Beam needs to allow zoom with mouse scroll similar to other RAM modules.
Guest over 3 years ago in  3 Future consideration

Allow user assigned steel beam camber

As part of user assigned beam sizing, occasionally would like to override the default camber value reported.
Guest over 3 years ago in  0 Needs review

Torsion Capacity Reporting

See PRODUCT BACKLOG ITEM 1677993 In RAM Concrete Beam and Column, we report 0.75*Tn, which is actually 0.75*Tth (see ACI 318-19 22.7.4.1). I recommend using that notation in Concrete Beam and Column Design reports when ACI 318-14 or ACI318-19 is u...
Guest about 1 month ago in  0 Needs review

RAM SS- Axial Design Check for Braced Frame/Collector Beams

Adding an axial design check for beams or collectors to a braced frame lateral frame system. In particularly for rigid diaphragms these forces are not applied to horizontal members and require separate hand checks or analysis in another program. T...
Jared Ganstine Ganstine over 3 years ago in  0 Needs review